Applications
- Drinking water
- Process optimisation of wastewater treatment plants
- Industrial and municipal wastewater
- Mineral water monitoring
- Surface water
Description
The 3S colorimeter is a compact analytical instrumentation for online analysis and process monitoring. The colorimeter is based on a color-developing chemical reaction carried out inside the analyzer's glass cell. The sample, coming from an external reservoir or process stream is autonomously grabbed by the instrument and mixed with the appropriate reagents to make the reaction happen. The analyzer uses an LED light source and a photodiode to photometrically measure the developed color intensity (absorbance). The absorbance is proportional to the concentration of the target chemical species (analite).
Features:
- Low reagents consumption and analytical reliability thanks to our custom designed miniature peristaltic pumps
- Dual compartment design to guarantee a complete separation between the electronics and the hydraulic section
- Color touchscreen to show the last measured value clearly, and to set all the options and settings via an user friendly interface
- Datalogger function with data history in graphical form and USB download
- Automatic calibration, validation and cleaning to reduce down time and operator intervention, their frequency can be freely set by the user
- Fully integrable in industrial automation via the analog outputs (2 x 4-20 mA channels), digital output (2 relays + ModbusRTU) and digital input (voltage free contact)
Multiparameter online analyzer for the determination of nitrites and nitrates in water.
The instrument is ideal for potable water or suface water analysis and with the addition of a dilution module is also capable of the determination of nitrites and nitrates in complex matrices such as urban and industrial wastewaters.
Method
In acidic media, nitrites react with sulfanilamide and N-(1-naphthyl)-ethylene diammonium dichloride, forming a purple colored dye. The absorbance intensity is proportional to the nitrites concentration in the sample and is determined at 525 nm.
Features
Measured parameter | NO2- | ||||||
Range
|
|||||||
Reproducibility*
|
|||||||
Limit of detection | 5 ppb |
Wavelength | 525 nm | ||||
Demineralized water | Not required | ||||
Interferences | Amines, urea, iodides. | ||||
Reference | DIN EN 26 777 | ||||
Number of reagents | 2 | ||||
Min. analysis time | 7 minutes | ||||
Default analysis time | 15 minutes | ||||
Reagent consumption**
|
Reagents and standards
Safety Datasheet
Both hydrazine and copper catalyst reagents are used to reduce Nitrate to Nitrite in a basic medium inside a heated reaction cell. A sulfanilamide and N-(1-naphthyl)-ethylene diammonium dichloride reagent is added to react with the Nitrite to form a purple colored compound. The absorbance intensity is proportional to the Nitrite concentration in the sample and is measured at 525 nm
Features
Measured parameter | NO3- | ||||||
Range
|
|||||||
Reproducibility*
|
|||||||
Limit of detection | 2 ppb |
Wavelength | 525 nm | ||
Demineralized water | Not required | ||
Termoregulation | 37 °C | ||
Interferences | Amines, urea, iodides. | ||
Reference | DIN EN 26 777 | ||
Number of reagents | 3 | ||
Min. analysis time | 11 minutes | ||
Default analysis time | 20 minutes | ||
Reagent consumption**
|
Reagents and standards
Safety Datasheet
Technical Specifications
Model | 3S-CL |
Sampling Mode | Batch, with freely settable frequency. |
Sample | Pressure: Atmospheric Temperature: 5 ‐ 45°C (41 ‐ 113°F) Flow Rate: 80 to 500 mL/min Connection: 6 mm (¼-in.) |
Drain |
Pressure-free drain Connection: 12 mm (½-in.) |
Input Streams | 2 |
Material | Epoxy-coated stainless steel AISI 304 |
Dimensions (H x W x D) | 604 x 380 x 210 mm (23.6 x 14.8 x 8.2 in) |
Weight | 20 kg (44 lbs) |
Power Supply |
Input Voltage: 115 VAC,230 VAC Power consumption: max. 80 W |
Output signals |
2 x 4-20 mA analog outputs Modbus via RS485,Ethernet |
Alarms | 2 SPDT programmable voltage-free relays |
Digital Input | None, Online, Start Extra, Skip Idle, Emergency Stop |
Ambient Temperature | 5 - 45 °C (41 - 113 °F) |
Ambient Humidity | 10 - 90 % RH (non-condensing) |
Protection Grade | IP54 (indoor only, outdoor use possible with external cabinet, not included) |
Documentation
Related Accessories
- SS external reservoir with level switch for dilution water
- Fast Loop external reservoir with level switch - polycarbonate
- SS External reservoir with level switch for sample
- PVC external reservoir with level switch
- ENCLOSURE FOR OUTDOOR OPERATION
- Filtration unit 100 micron 230 VAC
- Sampling Pump
- Stainless steel continuous flow D.50 sensor holder
- PVC continuous flow D.50 sensor holder
- STAINLESS STEEL CONTINUOS FLOW DOUBLE PROBE HOLDER
- Immersion pipe for online sensors